Structural calculations for your drawings - Signed, Sealed, Delivered!
Beams, lintels, joists and rafters, in wood or steel. Upload your drawing set and choose the members. Every value is read from your sheets and shows where it came from. An independent P.Eng. or BCIN sealer of your choice reviews, calculates and seals only the members you choose, and every seal can be checked by the building department.
How it works
Your drawing set stays the source. Nothing is retyped: each span, width and load points back to the sheet it came from.
Upload your drawing set
The PDF exported straight from your drawing program. We check that the framing sheets can be measured. Optional, recommended: add a DXF of the same plans, and a 3D DXF of the model as well. They confirm what is read from the PDF, find post sizes, supports and loads from above the PDF doesn't show, and ask about anything that disagrees. The PDF stays the record that is sealed.
Choose the beams
Enter the tags (B-1, B-2…). We find each one and read its size, supports, span, joists and the loads noted on the sheet.
Answer and submit
Anything unclear on the drawings comes back as a plain question. Answer, correct what's needed, and submit. The project locks while we review it.
A sealer reviews and seals
Choose a P.Eng. or a BCIN sealer. They confirm every value, calculate to OBC 2024 and CSA O86-19, and seal the beams that pass. You download sealed sheets and the calculation reports.
Who it's for
Builders and designers who need structural calculations behind a permit set, without redrawing anything.
Builders and contractors
- Keep all your projects in one place and pick them up any time before you submit.
- Only the beams you choose are sealed, and each one is marked on its sheet.
- Need a change after submitting? Start a new revision. The submitted one stays on record.
Design firms (BCIN)
- Upload the set exactly as issued. Revision and print date are read from your title block.
- Beams drawn as outlines or as single lines, column symbols, LINE LOAD notes and wall offsets are all read.
- Full and reduced calculation reports, with every input cited to its sheet.
Pricing
A fixed price per beam, shown before you submit. You choose who seals it. Each beam is checked before you pay, so you know what will pass.
BCIN qualified designer
$195 first beam
$95 each additional beam on the same submission
Professional engineer (P.Eng.)
$295 first beam
$175 each additional beam on the same submission
Plus HST. The first-member price is the minimum per submission. A member sealed on an earlier revision of the same project is re-sealed at 50% of its price.
The clock pauses while a question waits for your answer, and resumes when you answer. Working hours are Monday to Friday, 8:00 a.m. to 6:00 p.m. Eastern, not counting Ontario statutory holidays.
Building officials: verify a seal
Every seal issued through RidgeMark Structural is printed with a verification code and QR code, bound to one project, address and drawing revision. Scan the QR code or enter the code to see exactly which beams it covers, and check the PDF you received against the issued file.
The code ties the seal to this drawing set
The code on the stamp opens a page showing the address, revision and beams the seal covers. If the code doesn't verify, or the page shows a different address, revision or beams than your copy, that code does not cover your copy. You can also call 705-704-9393 or email les@ridgemarkstructural.ca with the code.
P.Eng. or BCIN? Seal with RidgeMark Structural
Licensed engineers and qualified designers (BCIN) can review and seal beams for builders and designers. Projects arrive on a board with every value already read from the drawings and cited to its sheet. Take one at a time, review it, and seal it under your own name.
We are starting with a small group of sealers. Register your interest and, when a place opens, we will email you a personal link to apply. Questions? Call 705-704-9393.
Register your interestWhat we check before you can seal
- Your licence or BCIN, its status and categories, on the public registry.
- That you are you: we call the number the registry lists for you and ask for the code we emailed you.
- Your firm's registration, and for engineers, your professional liability insurance.
- Your signed sealer agreement: you are responsible for what you seal.
Getting the best read from your drawings
Export, don't print
Export the PDF from your drawing program (Chief Architect: File › Export › Export PDF). Printing to a PDF printer can turn sheets into pictures, which can't be measured.
Add the DXF too
Optional. Export a DXF of the same plans (Chief Architect: File › Export › Export Drawing, DXF) and drop it on the DXF box under your drawing set. Lengths are confirmed, missing post sizes are found, and differences come back as questions, so you can add what's missing to the PDF before it is sealed. Then add the 3D DXF of the model too: member sizes, what stands under each member, what lands on it from above, roof pitch and heights are checked against it.
Tag and note
Give every beam a tag (B-1, B-2…), keep the climatic & design load table on the set, note wall loads (LINE LOAD D=… L=… S=… PLF) and loads from posts above (POINT LOAD D=… L=… S=… LBS, with a leader to where the post lands), and fill in the revision table. Schedules pasted in as pictures are read too. Full detailing checklist
Contact
RidgeMark Structural
11 James Street, Seguin, Ontario P2A 0B6